On ti, 2017-05-02 at 12:49 +0100, Chris Wilson wrote:
> When we query the available eu on each subslice, we currently only
> report the max. It would also be useful to report the minimum found as
> well.
> 
> When we set RPCS (power gating over the EU), we can also specify both
> the min and max number of eu to configure on each slice; currently we
> just set it to a single value, but the flexibility may be beneficial in
> future.
> 
> Signed-off-by: Chris Wilson <ch...@chris-wilson.co.uk>

Reviewed-by: Joonas Lahtinen <joonas.lahti...@linux.intel.com>

Regards, Joonas
-- 