== Series Details ==

Series: Send a hotplug when edid changes (rev2)
URL   : https://patchwork.freedesktop.org/series/62816/
State : warning

== Summary ==

$ dim checkpatch origin/drm-tip
4a0b026f1681 drm: Add helper to compare edids.
-:32: CHECK:COMPARISON_TO_NULL: Comparison to NULL could be written "edid1"
#32: FILE: drivers/gpu/drm/drm_edid.c:1375:
+       bool edid1_present = edid1 != NULL;

-:33: CHECK:COMPARISON_TO_NULL: Comparison to NULL could be written "edid2"
#33: FILE: drivers/gpu/drm/drm_edid.c:1376:
+       bool edid2_present = edid2 != NULL;

-:39: CHECK:BRACES: Blank lines aren't necessary after an open brace '{'
#39: FILE: drivers/gpu/drm/drm_edid.c:1382:
+       if (edid1) {
+

-:54: CHECK:LINE_SPACING: Please don't use multiple blank lines
#54: FILE: drivers/gpu/drm/drm_edid.c:1397:
+
+

total: 0 errors, 0 warnings, 4 checks, 54 lines checked
0910fd34e6ab drm: Introduce change counter to drm_connector
-:42: CHECK:PREFER_KERNEL_TYPES: Prefer kernel type 'u64' over 'uint64_t'
#42: FILE: drivers/gpu/drm/drm_probe_helper.c:779:
+       uint64_t old_epoch_counter;

-:69: WARNING:BRACES: braces {} are not necessary for single statement blocks
#69: FILE: drivers/gpu/drm/drm_probe_helper.c:811:
+               if (old_status != connector->status) {
                        changed = true;
+               }

-:102: CHECK:PREFER_KERNEL_TYPES: Prefer kernel type 'u64' over 'uint64_t'
#102: FILE: include/drm/drm_connector.h:1285:
+       uint64_t epoch_counter;

total: 0 errors, 1 warnings, 2 checks, 69 lines checked
7d356e798c65 drm/i915: Send hotplug event if edid had changed.
-:8: WARNING:COMMIT_LOG_LONG_LINE: Possible unwrapped commit description 
(prefer a maximum 75 chars per line)
#8: 
to calling layer using drm_connector->change_counter(proposed by Daniel Vetter).

-:45: CHECK:PARENTHESIS_ALIGNMENT: Alignment should match open parenthesis
#45: FILE: drivers/gpu/drm/i915/display/intel_dp.c:5522:
+               DRM_DEBUG_KMS("[CONNECTOR:%d:%s] Edid was changed! Updating 
blob property.\n",
+                   connector->base.id, connector->name);

-:82: CHECK:PARENTHESIS_ALIGNMENT: Alignment should match open parenthesis
#82: FILE: drivers/gpu/drm/i915/display/intel_hdmi.c:2535:
+               DRM_DEBUG_KMS("[CONNECTOR:%d:%s] Edid was changed! Updating 
blob property.\n",
+                   connector->base.id, connector->name);

-:132: CHECK:PARENTHESIS_ALIGNMENT: Alignment should match open parenthesis
#132: FILE: drivers/gpu/drm/i915/display/intel_hotplug.c:293:
+               DRM_DEBUG_KMS("[CONNECTOR:%d:%s] status updated from %s to 
%s(change counter %llu)\n",
                      connector->base.base.id,

total: 0 errors, 1 warnings, 3 checks, 101 lines checked