This allows us to use all 4 fdi lanes on fdi B when the cpu eDP is
running on pipe C. Yay!

v2: Encapsulate test into a little helper function, as suggested by
Chris Wilson.

Signed-off-by: Daniel Vetter <daniel.vet...@ffwll.ch>
---
 drivers/gpu/drm/i915/intel_display.c | 18 +++++++++++++-----
 1 file changed, 13 insertions(+), 5 deletions(-)

diff --git a/drivers/gpu/drm/i915/intel_display.c 
b/drivers/gpu/drm/i915/intel_display.c
index 6bcb196..c25dbdd 100644
--- a/drivers/gpu/drm/i915/intel_display.c
+++ b/drivers/gpu/drm/i915/intel_display.c
@@ -2381,6 +2381,11 @@ static void intel_fdi_normal_train(struct drm_crtc *crtc)
                           FDI_FE_ERRC_ENABLE);
 }
 
+static bool pipe_has_enabled_pch(struct intel_crtc *intel_crtc)
+{
+       return intel_crtc->base.enabled && intel_crtc->config.has_pch_encoder;
+}
+
 static void ivb_modeset_global_resources(struct drm_device *dev)
 {
        struct drm_i915_private *dev_priv = dev->dev_private;
@@ -2390,10 +2395,13 @@ static void ivb_modeset_global_resources(struct 
drm_device *dev)
                to_intel_crtc(dev_priv->pipe_to_crtc_mapping[PIPE_C]);
        uint32_t temp;
 
-       /* When everything is off disable fdi C so that we could enable fdi B
-        * with all lanes. XXX: This misses the case where a pipe is not using
-        * any pch resources and so doesn't need any fdi lanes. */
-       if (!pipe_B_crtc->base.enabled && !pipe_C_crtc->base.enabled) {
+       /*
+        * When everything is off disable fdi C so that we could enable fdi B
+        * with all lanes. Note that we don't care about enabled pipes without
+        * an enabled pch encoder.
+        */
+       if (!pipe_has_enabled_pch(pipe_B_crtc) &&
+           !pipe_has_enabled_pch(pipe_C_crtc)) {
                WARN_ON(I915_READ(FDI_RX_CTL(PIPE_B)) & FDI_RX_ENABLE);
                WARN_ON(I915_READ(FDI_RX_CTL(PIPE_C)) & FDI_RX_ENABLE);
 
@@ -3996,7 +4004,7 @@ static bool ironlake_check_fdi_lanes(struct drm_device 
*dev, enum pipe pipe,
                }
                return true;
        case PIPE_C:
-               if (!pipe_B_crtc->base.enabled ||
+               if (!pipe_has_enabled_pch(pipe_B_crtc) ||
                    pipe_B_crtc->config.fdi_lanes <= 2) {
                        if (pipe_config->fdi_lanes > 2) {
                                DRM_DEBUG_KMS("invalid shared fdi lane config 
on pipe %i: %i lanes\n",
-- 
1.7.11.7

_______________________________________________
Intel-gfx mailing list
Intel-gfx@lists.freedesktop.org
http://lists.freedesktop.org/mailman/listinfo/intel-gfx

Reply via email to