Hi Jean,

On 2017/10/6 21:31, Jean-Philippe Brucker wrote:
> -     if (domain->ext_handler) {
> +     if (domain->handler_flags & IOMMU_FAULT_HANDLER_ATOMIC) {
> +             fault->flags |= IOMMU_FAULT_ATOMIC;

Why remove the condition of domain->ext_handler? should it be much better like:
  if ((domain->handler_flags & IOMMU_FAULT_HANDLER_ATOMIC) && 
domain->ext_handler)

If domain->ext_handler is NULL, and (domain->handler_flags & 
IOMMU_FAULT_HANDLER_ATOMIC)
is true. It will oops, right?

>               ret = domain->ext_handler(domain, dev, fault,
>                                         domain->handler_token);

Thanks
Yisheng Xie

_______________________________________________
iommu mailing list
iommu@lists.linux-foundation.org
https://lists.linuxfoundation.org/mailman/listinfo/iommu