Yes those should be just INFO messages (or no messages) and not WARNING/ERROR. 
Fixing now...

Jira ticket already created by Soemin: https://jira.iotivity.org/browse/IOT-2357

Regards,
Ibrahim

-----Original Message-----
From: Daniel Mihai 
Sent: Wednesday, May 24, 2017 4:51 PM
To: Mats Wichmann <mats at wichmann.us>; IoTivity Developer List <iotivity-dev 
at lists.iotivity.org>
Cc: Ibrahim Esmat <iesmat at microsoft.com>
Subject: RE: [dev] odd msgs in windows x86 build logs

I think the large sequence of *contiguous* ERRORs below makes these log entries 
look scarier than they probably are. If these ERRORs are actually spread across 
multiple tests, many of them don't look surprising to me.

Probably windows x86 is the only Jenkins build job that runs with LOGGING=1, 
which explains why the output looks so different than the other build jobs.

I agree that the IoTivity logs should be reviewed and improved. For example, 
please log a JIRA ticket for these suspect log entries, or let me know if you 
prefer me to log that ticket:

12:53:16 53:13.122 WARNING: OIC_PLATFORM: Unsupported platform.
12:53:16 53:13.122 ERROR: OIC_PLATFORM: Failed to GetSysLocalAppDataPath, ret: 3

Thanks,
Dan

-----Original Message-----
From: iotivity-dev-bounces at lists.iotivity.org 
[mailto:[email protected]] On Behalf Of Mats Wichmann
Sent: Wednesday, May 24, 2017 3:00 PM
To: IoTivity Developer List <iotivity-dev at lists.iotivity.org>
Subject: [dev] odd msgs in windows x86 build logs


from jira, a failed build:
https://na01.safelinks.protection.outlook.com/?url=https%3A%2F%2Fbuild.iotivity.org%2Fci%2Fjob%2Fiotivity-verify-windows-x86-vs2013%2F1978%2Fconsole&data=02%7C01%7CDaniel.Mihai%40microsoft.com%7C1c5c4a9c000b45b0981208d4a2f039cc%7C72f988bf86f141af91ab2d7cd011db47%7C1%7C0%7C636312600048564193&sdata=3X%2Bjp%2BBiA60SG4U0jcOnQtsqHCwhra0tJIlEFaGhRHk%3D&reserved=0:

12:53:16 53:13.122 WARNING: OIC_PLATFORM: Unsupported platform.
12:53:16 53:13.122 ERROR: OIC_PLATFORM: Failed to GetSysLocalAppDataPath, ret: 3

is this something expected?

A succeeded build here also has a lot of unexpected stuff in it:

https://na01.safelinks.protection.outlook.com/?url=https%3A%2F%2Fbuild.iotivity.org%2Fci%2Fjob%2Fiotivity-verify-windows-x86-vs2015%2F1973%2Fconsole&data=02%7C01%7CDaniel.Mihai%40microsoft.com%7C1c5c4a9c000b45b0981208d4a2f039cc%7C72f988bf86f141af91ab2d7cd011db47%7C1%7C0%7C636312600048564193&sdata=uDsiefIdonlBHVZjnRbT9eGQDUL4bvG8WQMgwE8Nhwg%3D&reserved=0

there are 4228 lines in the full log that contain the tag ERROR:, the unique 
list of those messages follows. Since I don't see any of those in an x64 
windows build, it seems kind of surprising all those would happen and the build 
would still be marked a succeed... are these some kind of debug output that are 
triggering on

ERROR: OI45:10.705 DEBUG: OIC_CA_CONN_MGR: CAInitialize type : 1
ERROR: OIC_45:10.692 DEBUG: OIC_CA_CONN_MGR: CAInitialize type : 1
ERROR: OIC_CA_ADAP_UTILS: Failed at parse ipv6 address using inet_pton
ERROR: OIC_CA_BWT: no logic [0]
ERROR: OIC_CA_IP_SERVER: WSAEventSelect failed 10038
ERROR: OIC_CA_MSG_HANDLE: Failed to generate unicast PDU
ERROR: OIC_CA_MSG_HANDLE: Invalid input: sendMsg
ERROR: OIC_CA_MSG_HANDLE: send failed:7
ERROR: OIC_CA_PRTCL_MSG: Invalid input: token
ERROR: OIC_CA_PRTCL_MSG: reset is not empty message
ERROR: OIC_CA_QING: thread instance is empty..
ERROR: OIC_CA_TCP_SERVER: WSAEventSelect failed 10093
ERROR: OIC_PLATFORM: Failed to GetSysLocalAppDataPath, ret: 3
ERROR: OIC_RI_PAYLOADPARSE: Array details weren't clear with cbor error:
'unknown error'.
ERROR: OIC_RI_PAYLOADPARSE: Array parse failed, mixed arrays not allowed
ERROR: OIC_RI_RESOURCE: No value specified.
ERROR: OIC_RI_RESOURCE: Null or empty device name.
ERROR: OIC_RI_RESOURCE: Platform ID is not a UUID.
ERROR: OIC_RI_RESOURCE: Platform Resource does not exist.
ERROR: OIC_RI_RESOURCE: R[==========] 5 tests from 2 test cases ran. (2 ms 
total)
ERROR: OIC_RI_RESOURCE: ReadDatabaseFromPS failed
ERROR: OIC_RI_RESOURCE: ReadDevicePropertiesFromDatabase failed
ERROR: OIC_RI_RESOURCE: The passed value cannot be empty
ERROR: OIC_RI_RESOURCE: The passed value is bigger than permitted.
ERROR: OIC_RI_STACK: Added handle equals collection handle
ERROR: OIC_RI_STACK: collectionHandle is NULL
ERROR: OIC_RI_STACK: handle is NULL
ERROR: OIC_RI_STACK: Input parameter is NULL
ERROR: OIC_RI_STACK: Invalid callback
ERROR: OIC_RI_STACK: Invalid handle for deletion
ERROR: OIC_RI_STACK: Invalid mode
ERROR: OIC_RI_STACK: Invalid parameters
ERROR: OIC_RI_STACK: Invalid property
ERROR: OIC_RI_STACK: Invalid TPS Types OC_ALL
ERROR: OIC_RI_STACK: OCEncodeAddressForRFC6874 failed: encoded output will not 
fit!
ERROR: OIC_RI_STACK: OCEncodeAddressForRFC6874 failed: Input string is already 
encoded
ERROR: OIC_RI_STACK: OCProcess has failed. ocstack is not initialized
ERROR: OIC_RI_STACK: Resource /a/led already exists
ERROR: OIC_RI_STACK: resourceInterfaceName is NULL
ERROR: OIC_RI_STACK: Resource not found
ERROR: OIC_RI_STACK: resource type illegal (see RFC 6690)
ERROR: OIC_RI_STACK: resourceTypeName is NULL
ERROR: OIC_RI_STACK: URI is empty or too long
ERROR: OIC_SRM_PSI: (OC_STACK_OK == ret) failed!!
ERROR: OIC_SRM_PSI: ps is NULL
ERROR: OIC_ULINKLIST: Invalid input: linklist is null
ERROR: OIC_UMUTEX: oc_mutex_lock Invalid mutex !
ERROR: OIC_UMUTEX: oc_mutex_unlock: Invalid mutex !
_______________________________________________
iotivity-dev mailing list
iotivity-dev at lists.iotivity.org
https://na01.safelinks.protection.outlook.com/?url=https%3A%2F%2Flists.iotivity.org%2Fmailman%2Flistinfo%2Fiotivity-dev&data=02%7C01%7CDaniel.Mihai%40microsoft.com%7C1c5c4a9c000b45b0981208d4a2f039cc%7C72f988bf86f141af91ab2d7cd011db47%7C1%7C0%7C636312600048564193&sdata=XnJdzbykbql8amczq62dEEptRJw0jK%2BsLYK6QDIM0iI%3D&reserved=0