Hi, Has anybody tried the Data Center Manageability Interface (DCMI) Conformance Test suite (DCTS) from http://www.intel.com/technology/product/dcmi/ ? DCMI sits on top of IPMI 2.0 and defines a set of commands specific fort Data Center / Internet Portal Servers (for details see DCMI spec.)
Unfortunately there is no direct feedback alias listed on the Intel DCMI Web site, so if anyone from Intel on this list could forward this comments this would be very appreciated. Thanks. Test Case 5.5: Verify SEL Clear Action. Is trying to get the status of the previous Clear SEL command, but re-uses the previous Reservation ID from the original Clear SEL command. According to section 31.4.2 of the IPMI 2.0 spec. a clear SEL should cancel the present reservation. Re-sending a clear SEL with the same reservation ID will therefore result in a completion code 0xC5 (invalid reservation) on some/most BMC's and the DCTS test case will be reported as FAIL. Test Case 7.1: Checking Chassis Status for Initial Power State. The test checks for a fixed 3 byte response and reports the optional Front Panel Button Capabilities as invalid length. There is a define CHASSIS_STATUS_MAX_RSPLEN (5) in addition to CHASSIS_STATUS_MIN_RSPLEN (3), which is unused and which IMHO should be (4) to reflect the Front Panel Button Capabilities response byte. Thanks Holger Liebig -- Holger L i e b i g holger.lie...@fujitsu-siemens.com Fujitsu Siemens Computers GmbH Senior Developer Otto Hahn Ring 6 IP SW SV 4 81739 Munich Telephone: +49 89 636 43820 GERMANY Telefax : +49 89 636 41215 Internet http://www.fujitsu-siemens.com Company Details http://www.fujitsu-siemens.com/imprint.html ------------------------------------------------------------------------------ _______________________________________________ Ipmitool-devel mailing list Ipmitool-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/ipmitool-devel