The PE1750 only supports IPMI 1.0, so does not have a LAN or LAN+ channel (this only supported on IPMI 1.5+) For legacy servers, you can see which version of IPMI is supported at: http://linux.dell.com/ipmi.shtml
--jordan hargrave Dell Enterprise Linux Engineering -----Original Message----- From: Radu Gheorghiu [mailto:r...@pengooin.net] Sent: Friday, September 17, 2010 9:54 AM To: Andy Cress; ipmitool-devel@lists.sourceforge.net Subject: Re: [Ipmitool-devel] IPMI on Dell PE-1750 Hello Andy, Thank you very much for your reply. Indeed i had great succes with ipmiutil on Dell PE-1850, 1950, SC1425, However PE-1750 is a bit strange. It appears it does not have a LAN channel. By checking dmidecode, i find this: IPMI Device Information Interface Type: BT (Block Transfer) Specification Version: 1.0 I2C Slave Address: 0x10 NV Storage Device: Not Present Base Address: 0x00000000000000E4 (I/O) Register Spacing: Successive Byte Boundaries Interrupt Polarity: Active High Interrupt Trigger Mode: Edge Interrupt Number: a By issuing ipmiutil lan i get this output: ipmiutil ver 2.69 ilan ver 2.69 -- BMC version 1.80, IPMI version 1.0 This IPMI v1.0 system does not support PEF records. This system does not support IPMI LAN channels. Could it be that PE-1750 does not have a LAN channel? I find it very odd. Regards, Radu ------------------------------------------------------------------------------ Start uncovering the many advantages of virtual appliances and start using them to simplify application deployment and accelerate your shift to cloud computing. http://p.sf.net/sfu/novell-sfdev2dev _______________________________________________ Ipmitool-devel mailing list Ipmitool-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/ipmitool-devel