Csaba Ringhofer created IMPALA-10536:
----------------------------------------

             Summary: saml2_callback_token_ttl's unit is seconds instead of 
milliseconds
                 Key: IMPALA-10536
                 URL: https://issues.apache.org/jira/browse/IMPALA-10536
             Project: IMPALA
          Issue Type: Bug
            Reporter: Csaba Ringhofer


The description of saml2_callback_token_ttl writes "seconds", while its value 
is interpreted as milliseconds, which the default 30 is way too short outside 
automatic tests.

I think that keeping the semantics and just rewriting the desc to milliseconds 
is better than fixing the semantics, because the very low ttl is actually 
useful for automatic tests that test expiration logic.



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

---------------------------------------------------------------------
To unsubscribe, e-mail: issues-all-unsubscr...@impala.apache.org
For additional commands, e-mail: issues-all-h...@impala.apache.org

Reply via email to