https://issues.apache.org/jira/browse/IMPALA-13276?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Fang-Yu Rao updated IMPALA-13276:
---------------------------------
    Labels:   (was: 4.4.1)

> Revise the documentation of query option 'RUNTIME_FILTER_WAIT_TIME_MS'
> ----------------------------------------------------------------------
>
>                 Key: IMPALA-13276
>                 URL: https://issues.apache.org/jira/browse/IMPALA-13276
>             Project: IMPALA
>          Issue Type: Documentation
>          Components: Docs
>            Reporter: Fang-Yu Rao
>            Assignee: Fang-Yu Rao
>            Priority: Major
>
> The documentation of the query option 'RUNTIME_FILTER_WAIT_TIME_MS' at 
> [https://github.com/apache/impala/blob/master/docs/topics/impala_runtime_filter_wait_time_ms.xml#L37-L43]
>  as provided in the following describes the meaning of this query option.
> {code:java}
>       The <codeph>RUNTIME_FILTER_WAIT_TIME_MS</codeph> query option
>       adjusts the settings for the runtime filtering feature.
>       It specifies a time in milliseconds that each scan node waits for
>       runtime filters to be produced by other plan fragments.
> {code}
>  
> However the description above is not entirely accurate in that the wait time 
> is with respect to the time when a runtime filter was registered (within 
> [QueryState::InitFilterBank()|https://github.com/apache/impala/blob/master/be/src/runtime/query-state.cc#L381])
>  instead of the time when a scan node is calling 
> [ScanNode::WaitForRuntimeFilters()|https://github.com/apache/impala/blob/master/be/src/exec/scan-node.cc#L212].
>  For instance if a scan node started so late that when 
> ScanNode::WaitForRuntimeFilters() was called, the amount of time passed since 
> the registration of this runtime filter was already greater than the value of 
> 'RUNTIME_FILTER_WAIT_TIME_MS', this scan node would not be waiting for the 
> runtime filter. Refer to 
> [https://github.com/apache/impala/blob/master/be/src/runtime/runtime-filter.cc#L86-L87]
>  for further details.
> {code:java}
> bool RuntimeFilter::WaitForArrival(int32_t timeout_ms) const {
>   unique_lock<mutex> l(arrival_mutex_);
>   while (arrival_time_.Load() == 0) {
>     int64_t ms_since_registration = MonotonicMillis() - registration_time_;
>     int64_t ms_remaining = timeout_ms - ms_since_registration;
>     if (ms_remaining <= 0) break;
>     if (injection_delay_ > 0) SleepForMs(injection_delay_);
>     arrival_cv_.WaitFor(l, ms_remaining * MICROS_PER_MILLI);
>   }
>   return arrival_time_.Load() != 0;
> }
> {code}
> We should revise the documentation to make it a bit clearer.



--
This message was sent by Atlassian Jira
(v8.20.10#820010)

---------------------------------------------------------------------
To unsubscribe, e-mail: issues-all-unsubscr...@impala.apache.org
For additional commands, e-mail: issues-all-h...@impala.apache.org

Reply via email to