[ https://issues.apache.org/jira/browse/DRILL-4829?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16401063#comment-16401063 ]
Venkata Jyothsna Donapati commented on DRILL-4829: -------------------------------------------------- This is incorporated in DRILL-6005. Configuring `drill.exec.allow_loopback_address_binding` option to true will allow binding to loopback address > Configure the address to bind to > -------------------------------- > > Key: DRILL-4829 > URL: https://issues.apache.org/jira/browse/DRILL-4829 > Project: Apache Drill > Issue Type: Improvement > Reporter: Daniel Stockton > Assignee: Venkata Jyothsna Donapati > Priority: Minor > Fix For: 1.14.0 > > > 1.7 included the following patch to prevent Drillbits binding to the loopback > address: https://issues.apache.org/jira/browse/DRILL-4523 > "Drillbit is disallowed to bind to loopback address in distributed mode." > It would be better if this was configurable rather than rely on /etc/hosts, > since it's common for the hostname to resolve to loopback. > Would you accept a patch that adds this option to drill.override.conf? -- This message was sent by Atlassian JIRA (v7.6.3#76005)