[ https://issues.apache.org/jira/browse/DRILL-5983?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel ]
Stuart Teasdale updated DRILL-5983: ----------------------------------- Attachment: test.parquet > Unsupported nullable converted type INT_8 for primitive type INT32 error > ------------------------------------------------------------------------ > > Key: DRILL-5983 > URL: https://issues.apache.org/jira/browse/DRILL-5983 > Project: Apache Drill > Issue Type: Bug > Components: Execution - Data Types > Affects Versions: 1.10.0, 1.11.0 > Environment: NAME="Ubuntu" > VERSION="16.04.2 LTS (Xenial Xerus)" > Reporter: Hakan Sarıbıyık > Priority: Major > Labels: parquet, read, types > Attachments: test.parquet > > > When I query a table with byte in it, then it gives an error; > _Query Failed: An Error Occurred > org.apache.drill.common.exceptions.UserRemoteException: SYSTEM ERROR: > ExecutionSetupException: Unsupported nullable converted type INT_8 for > primitive type INT32 Fragment 1:6 [Error Id: > 46636b05-cff5-455b-ba25-527217346b3e on bigdata7:31010]_ > Actualy, it has been solved with > [DRILL-4764] - Parquet file with INT_16, etc. logical types not supported by > simple SELECT > according to https://drill.apache.org/docs/apache-drill-1-10-0-release-notes/ > But i tried it with even 1-11-0 it didnt worked. > I am querying parquet formatted file with pySpark > tablo1 > sourceid: byte (nullable = true) > select sourceid from tablo1 > works as expected with pySpark. But not with Drill v1.11.0 > Thanx. -- This message was sent by Atlassian JIRA (v7.6.3#76005)