https://issues.apache.org/jira/browse/FLINK-6586?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16016156#comment-16016156
 ] 

ASF GitHub Bot commented on FLINK-6586:
---------------------------------------

Github user greghogan commented on the issue:

    https://github.com/apache/flink/pull/3907
  
    Does an `InputGate` contain both local and remote `InputChannel` such that 
the minimum positive value might be more desirable in that case?


> InputGateMetrics#refreshAndGetMin returns Integer.MAX_VALUE for local channels
> ------------------------------------------------------------------------------
>
>                 Key: FLINK-6586
>                 URL: https://issues.apache.org/jira/browse/FLINK-6586
>             Project: Flink
>          Issue Type: Bug
>          Components: Metrics, Network
>    Affects Versions: 1.3.0, 1.4.0
>            Reporter: Chesnay Schepler
>            Assignee: Chesnay Schepler
>            Priority: Trivial
>             Fix For: 1.3.0, 1.4.0
>
>
> The {{InputGateMetrics#refreshAndGetMin}} returns {{Integer.MAX_VALUE}} when 
> working with {{LocalChannels}}. In this case it should return 0 instead.



--
This message was sent by Atlassian JIRA
(v6.3.15#6346)

Reply via email to