Eron Wright  created FLINK-7752:
-----------------------------------

             Summary: RedirectHandler should execute on the IO thread
                 Key: FLINK-7752
                 URL: https://issues.apache.org/jira/browse/FLINK-7752
             Project: Flink
          Issue Type: Sub-task
            Reporter: Eron Wright 
            Priority: Minor


The redirect handler executes much of its logic (including 'respondAsLeader') 
on an arbitrary thread, but it would be cleaner to execute on the I/O thread by 
using `channelHandlerContext.executor()`.   Note that Netty allows writes on 
any thread but reads on the I/O thread.   



--