Github user kl0u commented on a diff in the pull request:
https://github.com/apache/flink/pull/4993#discussion_r150243346
--- Diff:
flink-queryable-state/flink-queryable-state-client-java/src/main/java/org/apache/flink/queryablestate/network/AbstractServerBase.java
---
@@ -260,25 +262,47 @@ private boolean attemptToBind(final int port) throws
Throwable {
/**
* Shuts down the server and all related thread pools.
*/
- public void shutdown() {
- LOG.info("Shutting down server {} @ {}", serverName,
serverAddress);
-
- if (handler != null) {
- handler.shutdown();
- handler = null;
- }
-
- if (queryExecutor != null) {
- queryExecutor.shutdown();
- }
+ public CompletableFuture<?> shutdownServer(Time timeout) throws
InterruptedException {
+ log.info("Shutting down {} @ {}", serverName, serverAddress);
+
+ final CompletableFuture<Boolean> queryExecShutdownFuture =
CompletableFuture.supplyAsync(() -> {
+ try {
+ if (queryExecutor != null &&
!queryExecutor.isShutdown()) {
+ queryExecutor.shutdown();
+
queryExecutor.awaitTermination(timeout.toMilliseconds(), TimeUnit.MILLISECONDS);
+ return true;
+ }
+ } catch (InterruptedException e) {
+ log.warn("Failed to shutdown {}: ",
serverName, e);
+ return false;
+ }
+ return false;
--- End diff --
We want to avoid pulling in the dependency of `runtime` here. Does it make
sense to move the `Executors` to another module, e.g. `core`.
---