https://issues.apache.org/jira/browse/FLINK-8178?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16287894#comment-16287894
 ] 

ASF GitHub Bot commented on FLINK-8178:
---------------------------------------

Github user NicoK commented on a diff in the pull request:

    https://github.com/apache/flink/pull/5105#discussion_r156389253
  
    --- Diff: 
flink-runtime/src/test/java/org/apache/flink/runtime/io/network/api/writer/RecordWriterTest.java
 ---
    @@ -558,4 +565,10 @@ public void read(DataInputView in) throws IOException {
                        return nextChannel;
                }
        }
    +
    +   private class ExpectedException extends RuntimeException {
    --- End diff --
    
    how about using Flink's `ExpectedTestException` instead?


> Introduce not threadsafe write only BufferBuilder
> -------------------------------------------------
>
>                 Key: FLINK-8178
>                 URL: https://issues.apache.org/jira/browse/FLINK-8178
>             Project: Flink
>          Issue Type: Improvement
>          Components: Network
>            Reporter: Piotr Nowojski
>            Assignee: Piotr Nowojski
>             Fix For: 1.5.0
>
>
> While Buffer class is used in multithreaded context it requires 
> synchronisation. Now it is miss-leading/unclear and suggesting that 
> RecordSerializer should take into account synchronisation of the Buffer 
> that's holding. With NotThreadSafe BufferBuilder there would be clear 
> separation between single-threaded writing/creating a BufferBuilder and 
> multithreaded Buffer handling/retaining/recycling.



--
This message was sent by Atlassian JIRA