https://issues.apache.org/jira/browse/FLINK-8718?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16371070#comment-16371070
]
Bowen Li commented on FLINK-8718:
---------------------------------
Hi [~gjy] , I looked at the code. As an extend, what's the difference between
the two variables {{DataSteamSource#isParallel}} and
{{SingleOutputStreamOperator#nonParallel}} ? I feel like they can actually be
consolidated into a single variable, but there's some refactoring needed. For
example, {{SingleOutputStreamOperator#setMaxParallelism()}} requires
{{Preconditions.checkArgument(canBeParallel() || maxParallelism == 1, xxx)}},
and it won't work if we consolidate the above two variables into one.
> Non-parallel DataStreamSource does not set max parallelism
> ----------------------------------------------------------
>
> Key: FLINK-8718
> URL: https://issues.apache.org/jira/browse/FLINK-8718
> Project: Flink
> Issue Type: Bug
> Components: Core
> Affects Versions: 1.5.0
> Reporter: Gary Yao
> Priority: Blocker
> Fix For: 1.5.0
>
>
> {{org.apache.flink.streaming.api.datastream.DataStreamSource}} does not set
> {{maxParallelism}} to 1 if it is non-parallel.
--