Shimin Yang commented on FLINK-10245:
-------------------------------------

Hi [~yuanoOo], I think the Increment operation should in the bussiness logic 
not the Sink. If we retrieve a value from HBase and then increment by one, then 
it will violate the consistency during recovery. For the pv senario, I suggest 
you can use the count in flink API and write to HBase in an overwrite fashion.