Jark Wu created FLINK-12351: ------------------------------- Summary: AsyncWaitOperator should deep copy StreamElement when object reuse is enabled Key: FLINK-12351 URL: https://issues.apache.org/jira/browse/FLINK-12351 Project: Flink Issue Type: Bug Reporter: Jark Wu Fix For: 1.9.0
Currently, AsyncWaitOperator directly put the input StreamElement into {{StreamElementQueue}}. But when object reuse is enabled, the StreamElement is reused, which means the element in {{StreamElementQueue}} will be modified. As a result, the output of AsyncWaitOperator might be wrong. An easy way to fix this might be deep copy the input StreamElement when object reuse is enabled, like this: https://github.com/apache/flink/blob/blink/flink-streaming-java/src/main/java/org/apache/flink/streaming/api/operators/async/AsyncWaitOperator.java#L209 -- This message was sent by Atlassian JIRA (v7.6.3#76005)