https://issues.apache.org/jira/browse/FLINK-12835?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

BoWang closed FLINK-12835.
--------------------------

> Time conversion is wrong in ManualClock
> ---------------------------------------
>
>                 Key: FLINK-12835
>                 URL: https://issues.apache.org/jira/browse/FLINK-12835
>             Project: Flink
>          Issue Type: Bug
>          Components: Tests
>    Affects Versions: 1.9.0
>            Reporter: BoWang
>            Assignee: BoWang
>            Priority: Minor
>              Labels: pull-request-available
>             Fix For: 1.7.3, 1.9.0, 1.8.1
>
>          Time Spent: 20m
>  Remaining Estimate: 0h
>
> `currentTime` stored in ManualClock is nanoseconds, when converted to 
> milliseconds is devided by 1_000L rather thant 1_000_000L.
> The test logic of `SlotPoolTest` using `ManualClock` should also be refined.



--
This message was sent by Atlassian JIRA
(v7.6.3#76005)

Reply via email to