https://issues.apache.org/jira/browse/FLINK-13910?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16995397#comment-16995397
 ] 

Yun Tang commented on FLINK-13910:
----------------------------------

[~aljoscha], the errors I provided are not related with checkpoint/savepoint 
but the job graph does not match on client and cluster side.

 

Shall we go through all classes per module and decide to modify classes at 
specific modes, e.g {{flink-core}}, {{flink-streaming-java}}, {{flink-runtime}} 
and so on?

> Many serializable classes have no explicit 'serialVersionUID'
> -------------------------------------------------------------
>
>                 Key: FLINK-13910
>                 URL: https://issues.apache.org/jira/browse/FLINK-13910
>             Project: Flink
>          Issue Type: Bug
>          Components: API / Type Serialization System
>            Reporter: Yun Tang
>            Assignee: Yun Tang
>            Priority: Critical
>             Fix For: 1.9.2, 1.10.0
>
>         Attachments: SerializableNoSerialVersionUIDField
>
>
> Currently, many serializable classes in Flink have no explicit 
> 'serialVersionUID'. As [official 
> doc|https://flink.apache.org/contributing/code-style-and-quality-java.html#java-serialization]
>  said, {{Serializable classes must define a Serial Version UID}}. 
> No 'serialVersionUID' would cause compatibility problem. Take 
> {{TwoPhaseCommitSinkFunction}} for example, since no explicit 
> 'serialVersionUID' defined, after 
> [FLINK-10455|https://github.com/apache/flink/commit/489be82a6d93057ed4a3f9bf38ef50d01d11d96b]
>  introduced, its default 'serialVersionUID' has changed from 
> "4584405056408828651" to "4064406918549730832". In other words, if we submit 
> a job from Flink-1.6.3 local home to remote Flink-1.6.2 cluster with the 
> usage of {{TwoPhaseCommitSinkFunction}}, we would get exception like:
> {code:java}
> org.apache.flink.streaming.runtime.tasks.StreamTaskException: Cannot 
> instantiate user function.
>         at 
> org.apache.flink.streaming.api.graph.StreamConfig.getStreamOperator(StreamConfig.java:239)
>         at 
> org.apache.flink.streaming.runtime.tasks.OperatorChain.<init>(OperatorChain.java:104)
>         at 
> org.apache.flink.streaming.runtime.tasks.StreamTask.invoke(StreamTask.java:267)
>         at org.apache.flink.runtime.taskmanager.Task.run(Task.java:711)
>         at java.lang.Thread.run(Thread.java:748)
> Caused by: java.io.InvalidClassException: 
> org.apache.flink.streaming.api.functions.sink.TwoPhaseCommitSinkFunction; 
> local class incompatible: stream classdesc serialVersionUID = 
> 4584405056408828651, local class serialVersionUID = 4064406918549730832
>         at java.io.ObjectStreamClass.initNonProxy(ObjectStreamClass.java:699)
>         at 
> java.io.ObjectInputStream.readNonProxyDesc(ObjectInputStream.java:1885)
>         at 
> java.io.ObjectInputStream.readClassDesc(ObjectInputStream.java:1751)
>         at 
> java.io.ObjectInputStream.readNonProxyDesc(ObjectInputStream.java:1885)
>         at 
> java.io.ObjectInputStream.readClassDesc(ObjectInputStream.java:1751)
>         at 
> java.io.ObjectInputStream.readOrdinaryObject(ObjectInputStream.java:2042)
>         at java.io.ObjectInputStream.readObject0(ObjectInputStream.java:1573)
>         at 
> java.io.ObjectInputStream.defaultReadFields(ObjectInputStream.java:2287)
>         at 
> java.io.ObjectInputStream.readSerialData(ObjectInputStream.java:2211)
>         at 
> java.io.ObjectInputStream.readOrdinaryObject(ObjectInputStream.java:2069)
>         at java.io.ObjectInputStream.readObject0(ObjectInputStream.java:1573)
>         at java.io.ObjectInputStream.readObject(ObjectInputStream.java:431)
>         at 
> org.apache.flink.util.InstantiationUtil.deserializeObject(InstantiationUtil.java:537)
>         at 
> org.apache.flink.util.InstantiationUtil.deserializeObject(InstantiationUtil.java:524)
>         at 
> org.apache.flink.util.InstantiationUtil.deserializeObject(InstantiationUtil.java:512)
>         at 
> org.apache.flink.util.InstantiationUtil.readObjectFromConfig(InstantiationUtil.java:473)
>         at 
> org.apache.flink.streaming.api.graph.StreamConfig.getStreamOperator(StreamConfig.java:224)
>         ... 4 more
> {code}
> Similar problems existed in  
> {{org.apache.flink.streaming.api.operators.SimpleOperatorFactory}} which has 
> different 'serialVersionUID' from release-1.9 and current master branch.
> IMO, we might have two options to fix this bug:
> # Add explicit serialVersionUID for those classes which is identical to 
> latest Flink-1.9.0 release code.
> # Use similar mechanism like {{FailureTolerantObjectInputStream}} in 
> {{InstantiationUtil}} to ignore serialVersionUID mismatch.
> I have collected all production classes without serialVersionUID from latest 
> master branch in the attachment, which counts to 639 classes.



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to