https://issues.apache.org/jira/browse/FLINK-15607?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17016504#comment-17016504
 ] 

Jingsong Lee commented on FLINK-15607:
--------------------------------------

> add restart process into the test to verify the accumulator state is correct

Good point, yes!

> throw exception when users trying to use Hive aggregate functions in 
> streaming mode
> -----------------------------------------------------------------------------------
>
>                 Key: FLINK-15607
>                 URL: https://issues.apache.org/jira/browse/FLINK-15607
>             Project: Flink
>          Issue Type: Improvement
>          Components: Connectors / Hive, Table SQL / API
>            Reporter: Bowen Li
>            Priority: Major
>
> Due to that Hive functions are all built for batch processing, aggregate 
> functions in Hive that implement UDAF and GenericUDAFResolver2 interfaces may 
> have unpredictable behaviors when used in streaming mode in Flink. We advice 
> users to only use Hive aggregate functions interfaces in batch mode.
>  
> It will be better to throw exception when users trying to use Hive aggregate 
> functions in streaming mode. Seems need to distinguish execution mode in 
> FunctionCatalogOperatorTable, which is not achievable yet.



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to