https://issues.apache.org/jira/browse/FLINK-17674?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Stephan Ewen resolved FLINK-17674.
----------------------------------
    Resolution: Fixed

Fixes in 1.11.0 via
  - e3413106ccd030e44d5e4690430c841370a1f988

> OperatorCoordinator state in checkpoints should always be a 
> ByteStreamStateHandle
> ---------------------------------------------------------------------------------
>
>                 Key: FLINK-17674
>                 URL: https://issues.apache.org/jira/browse/FLINK-17674
>             Project: Flink
>          Issue Type: Bug
>          Components: Runtime / Checkpointing
>            Reporter: Stephan Ewen
>            Assignee: Stephan Ewen
>            Priority: Minor
>             Fix For: 1.11.0
>
>
> State restore to the task vertices and coordinators (even after loading the 
> Checkpoint Metadata) happens in the JobManager's main thread and must 
> consequently not do any potentially blocking I/O operations.
> The OperatorCoordinator state is a generic {{StreamStateHandle}} whose state 
> might require I/O to retrieve. This never happens in the current 
> implementation (we always use {{ByteStreamStateHandle}}) the signatures and 
> contracts don't guarantee that and leave this open for a potential future bug.
> Typing the OperatorCoordinator state to ByteStreamStateHandle makes sure that 
> we can always retrieve the data directly without I/O and clarifies that no 
> arbitrary StreamStateHandle is supported at that point. 
> If state restoring becomes an asynchronous operation we can relax this 
> restriction.



--