curcur edited a comment on pull request #12353:
URL: https://github.com/apache/flink/pull/12353#issuecomment-635161998


   Hey @AHeise , I've spent some time walking through the code. I think the bug 
is clear that the consumer's  reference counter of `bufferBuilder` for 
`randomEmit` is not counted correctly. But I was wondering whether this fix 
work as expected in the case if the `record` to `randomEmit` is more than one 
buffer can hold.
   
   In `BroadcastRandomWriter#randomEmit`, random triggered data is emitted in 
the line of `emit(record, targetChannelIndex);`
   
   If you trace the code down, eventually data is serialized through 
`RecordWriter#copyFromSerializerToTargetChannel`
   
   and there, `requestNewBufferBuilder` is requested multiple times if the data 
to serialize is more than one buffer can hold.
   
   And as you can see, all the references to the remaining bufferBuilders are 
lost. Since the `addConsumer` in `randomEmit` is done after `emit(record, 
targetChannelIndex)`, it looks like so purely from the code perspective.
   
   But I am not quite familiar with this part of code, not sure whether this 
will cause real problems. 
   
   
   
   


----------------------------------------------------------------