https://issues.apache.org/jira/browse/FLINK-9253?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17212929#comment-17212929
 ] 

Zhijiang commented on FLINK-9253:
---------------------------------

[~NicoK]  I just closed the parent umbrella ticket for cleanup. Do you think we 
need to close this issue since it was not touched already long time and I am 
not quite sure whether it is worth focusing on future.
 

> Make buffer count per InputGate always #channels*buffersPerChannel + 
> ExclusiveBuffers
> -------------------------------------------------------------------------------------
>
>                 Key: FLINK-9253
>                 URL: https://issues.apache.org/jira/browse/FLINK-9253
>             Project: Flink
>          Issue Type: Sub-task
>          Components: Runtime / Network
>    Affects Versions: 1.5.0, 1.6.0
>            Reporter: Nico Kruber
>            Assignee: Nico Kruber
>            Priority: Major
>              Labels: pull-request-available
>             Fix For: 1.7.3
>
>          Time Spent: 10m
>  Remaining Estimate: 0h
>
> The credit-based flow control path assigns exclusive buffers only to remote 
> channels (which makes sense since local channels don't use any own buffers). 
> However, this is a bit intransparent with respect to how much data may be in 
> buffers since this depends on the actual schedule of the job and not the job 
> graph.
> By adapting the floating buffers to use a maximum of 
> {{#channels*buffersPerChannel + floatingBuffersPerGate - #exclusiveBuffers}}, 
> we would be channel-type agnostic and keep the old behaviour.



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to