https://issues.apache.org/jira/browse/FLINK-3554?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15179764#comment-15179764
]
ASF GitHub Bot commented on FLINK-3554:
---------------------------------------
Github user aljoscha commented on the pull request:
https://github.com/apache/flink/pull/1750#issuecomment-192241682
Yes, that's a problem. Could you maybe open an issue for that here:
https://issues.apache.org/jira/browse/FLINK
In the meantime, I have a workaround for you. You can use a modified
version of the CountTrigger:
```
public class ClosingCountTrigger<W extends Window> extends Trigger<Object,
W> {
private static final long serialVersionUID = 1L;
private final long maxCount;
private final ValueStateDescriptor<Long> stateDesc =
new ValueStateDescriptor<>("count",
LongSerializer.INSTANCE, 0L);
private ClosingCountTrigger(long maxCount) {
this.maxCount = maxCount;
}
@Override
public TriggerResult onElement(Object element, long timestamp, W
window, TriggerContext ctx) throws IOException {
ValueState<Long> count = ctx.getPartitionedState(stateDesc);
long currentCount = count.value() + 1;
count.update(currentCount);
if (currentCount >= maxCount) {
count.update(0L);
return TriggerResult.FIRE_AND_PURGE;
}
// register timer for final watermark
ctx.registerEventTimeTimer(Long.MAX_VALUE);
return TriggerResult.CONTINUE;
}
@Override
public TriggerResult onEventTime(long time, W window, TriggerContext
ctx) {
// final triggering
return TriggerResult.FIRE_AND_PURGE;
}
@Override
public TriggerResult onProcessingTime(long time, W window,
TriggerContext ctx) throws Exception {
return TriggerResult.CONTINUE;
}
@Override
public void clear(W window, TriggerContext ctx) throws Exception {
ctx.getPartitionedState(stateDesc).clear();
ctx.deleteEventTimeTimer(Long.MAX_VALUE);
}
@Override
public String toString() {
return "ClosingCountTrigger(" + maxCount + ")";
}
/**
* Creates a trigger that fires once the number of elements in a pane
reaches the given count.
*
* @param maxCount The count of elements at which to fire.
* @param <W> The type of {@link Window Windows} on which this trigger
can operate.
*/
public static <W extends Window> ClosingCountTrigger<W> of(long
maxCount) {
return new ClosingCountTrigger<>(maxCount);
}
}
```
you can use it like this:
```
stream
.keyBy(...)
.window(GlobalWindows.create())
.trigger(ClosingCountTrigger.of(<my count>)
.apply() // or .reduce()
```
This will behave like the normal count trigger but also register a callback
for the final `Long.MAX_VALUE` watermark. Then, when the final watermark
arrives it will trigger one last window emission.
> Bounded sources should emit a Max Watermark when they are done
> --------------------------------------------------------------
>
> Key: FLINK-3554
> URL: https://issues.apache.org/jira/browse/FLINK-3554
> Project: Flink
> Issue Type: Bug
> Components: Streaming
> Affects Versions: 1.0.0
> Reporter: Stephan Ewen
> Assignee: Stephan Ewen
> Priority: Blocker
> Fix For: 1.0.0
>
>
> For proper event time support in bounded sources, these sources should emit a
> final watermark before shutting down.
--
This message was sent by Atlassian JIRA
(v6.3.4#6332)