https://issues.apache.org/jira/browse/FLINK-21178?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

ASF GitHub Bot updated FLINK-21178:
-----------------------------------
    Labels: pull-request-available  (was: )

> Task failure will not trigger master hook's reset()
> ---------------------------------------------------
>
>                 Key: FLINK-21178
>                 URL: https://issues.apache.org/jira/browse/FLINK-21178
>             Project: Flink
>          Issue Type: Bug
>          Components: Runtime / Checkpointing
>    Affects Versions: 1.11.3, 1.12.0
>            Reporter: Brian Zhou
>            Priority: Major
>              Labels: pull-request-available
>
> In Pravega Flink connector integration with Flink 1.12, we found an issue 
> with our no-checkpoint recovery test case [1].
> We expect the recovery will call the ReaderCheckpointHook::reset() function 
> which was the behaviour before 1.12. However FLINK-20222 changes the logic, 
> the reset() call will only be called along with a global recovery. This 
> causes Pravega source data loss when failure happens before the first 
> checkpoint.
> [1]  
> [https://github.com/crazyzhou/flink-connectors/blob/da9f76d04404071471ebd86bf6889b307c9122ff/src/test/java/io/pravega/connectors/flink/FlinkPravegaReaderRGStateITCase.java#L78]



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to