https://issues.apache.org/jira/browse/FLINK-13372?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Flink Jira Bot updated FLINK-13372:
-----------------------------------
      Labels: auto-deprioritized-critical auto-unassigned  (was: 
auto-unassigned stale-critical)
    Priority: Major  (was: Critical)

This issue was labeled "stale-critical" 7 ago and has not received any updates 
so it is being deprioritized. If this ticket is actually Critical, please raise 
the priority and ask a committer to assign you the issue or revive the public 
discussion.


> Timestamp conversion bug in non-blink Table/SQL runtime
> -------------------------------------------------------
>
>                 Key: FLINK-13372
>                 URL: https://issues.apache.org/jira/browse/FLINK-13372
>             Project: Flink
>          Issue Type: Bug
>          Components: Table SQL / Legacy Planner
>    Affects Versions: 1.6.3, 1.6.4, 1.7.2, 1.8.0, 1.8.1, 1.9.0
>            Reporter: Shuyi Chen
>            Priority: Major
>              Labels: auto-deprioritized-critical, auto-unassigned
>
> Currently, in the non-blink table/SQL runtime, Flink used 
> SqlFunctions.internalToTimestamp(long v) from Calcite to convert event time 
> (in long) to java.sql.Timestamp.
> {code:java}
>  public static Timestamp internalToTimestamp(long v) { return new Timestamp(v 
> - (long)LOCAL_TZ.getOffset(v)); } {code}
> However, as discussed in the recent Calcite mailing list, 
> SqlFunctions.internalToTimestamp() assumes the input timestamp value is in 
> the current JVM’s default timezone (which is unusual), NOT milliseconds since 
> epoch. And SqlFunctions.internalToTimestamp() is used to convert timestamp 
> value in the current JVM’s default timezone to milliseconds since epoch, 
> which java.sql.Timestamp constructor takes. Therefore, the results will not 
> only be wrong, but change if the job runs in machines on different timezones 
> as well.(The only exception is that all your production machines uses UTC 
> timezone.)
> Here is an example, if the user input value is 0 (00:00:00 UTC on 1 January 
> 1970), and the table/SQL runtime runs in a machine in PST (UTC-8), the output 
> sql.Timestamp after SqlFunctions.internalToTimestamp() will become 28800000 
> millisec since epoch (08:00:00 UTC on 1 January 1970); And with the same 
> input, if the table/SQL runtime runs again in a different machine in EST 
> (UTC-5), the output sql.Timestamp after SqlFunctions.internalToTimestamp() 
> will become 18000000 millisec since epoch (05:00:00 UTC on 1 January 1970).
> Currently, there are unittests to test the table/SQL API event time 
> input/output (e.g., GroupWindowITCase.testEventTimeTumblingWindow() and 
> SqlITCase.testDistinctAggWithMergeOnEventTimeSessionGroupWindow()). They now 
> all passed because we are comparing the string format of the time which 
> ignores timezone. If you step into the code, the actual java.sql.Timestamp 
> value is wrong and change as the tests run in different timezone (e.g., one 
> can use -Duser.timezone=PST to change the current JVM’s default timezone)



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to