https://issues.apache.org/jira/browse/FLINK-23026?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Jark Wu closed FLINK-23026.
---------------------------
    Resolution: Not A Problem

> OVER WINDOWS function lost data
> -------------------------------
>
>                 Key: FLINK-23026
>                 URL: https://issues.apache.org/jira/browse/FLINK-23026
>             Project: Flink
>          Issue Type: Bug
>          Components: Table SQL / API, Table SQL / Client
>    Affects Versions: 1.12.1
>            Reporter: MOBIN
>            Priority: Critical
>         Attachments: image-2021-06-18-10-54-18-125.png
>
>
> {code:java}
> Flink SQL> CREATE TABLE tmall_item(
> >   itemID VARCHAR,
> >   itemType VARCHAR,
> >   eventtime varchar,
> >   onSellTime AS TO_TIMESTAMP(eventtime),
> >   price DOUBLE,
> >   WATERMARK FOR onSellTime AS onSellTime - INTERVAL '0' SECOND
> > ) with (
> >   'connector.type' = 'kafka',
> >    'connector.version' = 'universal',
> >    'connector.topic' = 'items',
> >    'format.type' = 'csv',
> >    'connector.properties.bootstrap.servers' = 'localhost:9092'
> > );
> >
> [INFO] Table has been created.
> Flink SQL> SELECT
> >     itemType,
> >     COUNT(itemID) OVER (
> >         PARTITION BY itemType
> >         ORDER BY onSellTime
> >         RANGE BETWEEN INTERVAL '1' DAY preceding AND CURRENT ROW) AS cot
> > FROM tmall_item;
> {code}
> When I enter the following data into the topic, its Electronic count value is 
> 3, which should normally be 4. If the event time and the value of the 
> partition field are the same, data will be lost
> ITEM001,Electronic,2017-11-11 10:01:00,20
>  {color:#ff0000}ITEM002{color},Electronic,{color:#ff0000}2017-11-11 
> 10:02:00{color},50
>  {color:#ff0000}ITEM002{color},Electronic,{color:#ff0000}2017-11-11 
> 10:02:00{color},50
>  ITEM003,Electronic,2017-11-11 10:03:00,50
> !image-2021-06-18-10-54-18-125.png|width=1156,height=192!



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to