https://issues.apache.org/jira/browse/FLINK-4016?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15317012#comment-15317012
]
ASF GitHub Bot commented on FLINK-4016:
---------------------------------------
Github user rvdwenden commented on the issue:
https://github.com/apache/flink/pull/2070
I checked in this change with this commit comment:
[FLINK-3977] initialize FoldApplyWindowFunction properly
Hopefully that’s enough, however, on Travis CI I see that on my commit, the
[FLINK-4016] is still triggered.
Regards, RvdWenden
> On 06 Jun 2016, at 09:46, Aljoscha Krettek <[email protected]>
wrote:
>
> Hi,
> I wrote in the issue that you opened. This is a duplicate of
https://issues.apache.org/jira/browse/FLINK-3977
<https://issues.apache.org/jira/browse/FLINK-3977> and the way to fix it is to
make InternalWindowFunction properly forward calls to setOutputType. If you
want, could you please change your fix to that and open a PR against the older
issue?
>
> —
> You are receiving this because you authored the thread.
> Reply to this email directly, view it on GitHub
<https://github.com/apache/flink/pull/2070#issuecomment-223889602>, or mute the
thread
<https://github.com/notifications/unsubscribe/ACoENn2sN0wGQAn7CaOt_c2R2i7utHKjks5qI9BKgaJpZM4ItrYw>.
>
> FoldApplyWindowFunction is not properly initialized
> ---------------------------------------------------
>
> Key: FLINK-4016
> URL: https://issues.apache.org/jira/browse/FLINK-4016
> Project: Flink
> Issue Type: Bug
> Components: DataStream API
> Affects Versions: 1.0.3
> Reporter: RWenden
> Priority: Blocker
> Labels: easyfix
> Fix For: 1.1.0
>
> Original Estimate: 1h
> Remaining Estimate: 1h
>
> FoldApplyWindowFunction's outputtype is not set.
> We're using constructions like (excerpt):
> .keyBy(0)
> .countWindow(10, 5)
> .fold(...)
> Running this stream gives an runtime exception in FoldApplyWindowFunction:
> "No initial value was serialized for the fold window function. Probably the
> setOutputType method was not called."
> This can be easily fixed in WindowedStream.java by (around line# 449):
> FoldApplyWindowFunction foldApplyWindowFunction = new
> FoldApplyWindowFunction<>(initialValue, foldFunction, function);
> foldApplyWindowFunction.setOutputType(resultType,
> input.getExecutionConfig());
> operator = new EvictingWindowOperator<>(windowAssigner,
>
> windowAssigner.getWindowSerializer(getExecutionEnvironment().getConfig()),
> keySel,
>
> input.getKeyType().createSerializer(getExecutionEnvironment().getConfig()),
> stateDesc,
> new
> InternalIterableWindowFunction<>(foldApplyWindowFunction),
> trigger,
> evictor);
--
This message was sent by Atlassian JIRA
(v6.3.4#6332)