[ https://issues.apache.org/jira/browse/FLINK-20443?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel ]
Arvid Heise updated FLINK-20443: -------------------------------- Fix Version/s: 1.15.0 > ContinuousProcessingTimeTrigger doesn't fire at the end of the window > --------------------------------------------------------------------- > > Key: FLINK-20443 > URL: https://issues.apache.org/jira/browse/FLINK-20443 > Project: Flink > Issue Type: Improvement > Components: API / DataStream > Reporter: Gee > Assignee: liwei li > Priority: Major > Labels: pull-request-available > Fix For: 1.15.0 > > > > {code:java} > srcStream > .timeWindowAll(Time.seconds(60)) > .trigger(ContinuousProcessingTimeTrigger.of(Time.seconds(10)))... > {code} > > This can correctly calculate the following interval result : 0-10s 10-20s > 20-30s 30-40s 40-50s > But this lost data which was send in 50-60s. > Because when the first window ends, the time is 59.9999s, it is not equal to > window-end-time(60s).So it will not enter the if judgment. -- This message was sent by Atlassian Jira (v8.3.4#803005)