https://issues.apache.org/jira/browse/FLINK-4175?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15388545#comment-15388545
 ] 

Felix Neutatz commented on FLINK-4175:
--------------------------------------

I started a design document here: 
https://docs.google.com/document/d/1odYIvmQt4feonQF9q-btBnGvrzzN3lX0Os6rzHcCOjA/edit?usp=sharing

I highly appreciate any idea or comment and I am looking forward to the 
discussion

> Broadcast data sent increases with # slots per TM
> -------------------------------------------------
>
>                 Key: FLINK-4175
>                 URL: https://issues.apache.org/jira/browse/FLINK-4175
>             Project: Flink
>          Issue Type: Improvement
>          Components: Core, TaskManager
>    Affects Versions: 1.0.3
>            Reporter: Felix Neutatz
>            Assignee: Felix Neutatz
>              Labels: performance
>
> Problem:
> we experience some unexpected increase of data sent over the network for 
> broadcasts with increasing number of slots per Taskmanager.
> We provided a benchmark [1]. It not only increases the size of data sent over 
> the network but also hurts performance as seen in the preliminary results 
> below. In this results cloud-11 has 25 nodes and ibm-power has 8 nodes with 
> scaling the number of slots per node from 1 - 16.
> +-----------------------+--------------+-------------+
> | suite                 | name         | median_time |
> +=======================+==============+=============+
> | broadcast.cloud-11    | broadcast.01 |        8796 |
> | broadcast.cloud-11    | broadcast.02 |       14802 |
> | broadcast.cloud-11    | broadcast.04 |       30173 |
> | broadcast.cloud-11    | broadcast.08 |       56936 |
> | broadcast.cloud-11    | broadcast.16 |      117507 |
> | broadcast.ibm-power-1 | broadcast.01 |        6807 |
> | broadcast.ibm-power-1 | broadcast.02 |        8443 |
> | broadcast.ibm-power-1 | broadcast.04 |       11823 |
> | broadcast.ibm-power-1 | broadcast.08 |       21655 |
> | broadcast.ibm-power-1 | broadcast.16 |       37426 |
> +-----------------------+--------------+-------------+
> After looking into the code base it, it seems that the data is de-serialized 
> only once per TM, but the actual data is sent for all slots running the 
> operator with broadcast vars and just gets discarded in case its already 
> de-serialized.
> We do not see a reason the data can't be shared among the slots of a TM and 
> therefore just sent once.
> [1] https://github.com/TU-Berlin-DIMA/flink-broadcast
> This Jira will continue the discussion started here: 
> https://mail-archives.apache.org/mod_mbox/flink-dev/201606.mbox/%3c1465386300767.94...@tu-berlin.de%3E



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Reply via email to