https://issues.apache.org/jira/browse/FLINK-25883?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Mikhail updated FLINK-25883:
----------------------------
    Description: 
In [this 
line|https://github.com/apache/flink/blob/fb38c99a38c63ba8801e765887f955522072615a/flink-python/pyflink/fn_execution/beam/beam_sdk_worker_main.py#L30],
 the value of DEFAULT_BUNDLE_PROCESSOR_CACHE_SHUTDOWN_THRESHOLD_S is set to 
3153600000. This is more than the default value of threading.TIMEOUT_MAX on 
Windows Python. Due to this, "OverflowError: timeout value is too large" error 
is produced.

Full traceback:
{code:java}
 File 
"G:\PycharmProjects\PyFlink\venv_from_scratch\lib\site-packages\apache_beam\runners\worker\data_plane.py",
 line 218, in run
  while not self._finished.wait(next_call - time.time()):
 File "C:\Python38\lib\threading.py", line 558, in wait
  signaled = self._cond.wait(timeout)
 File "C:\Python38\lib\threading.py", line 306, in wait
  gotit = waiter.acquire(True, timeout)
OverflowError: timeout value is too large{code}

  was:
In [this 
line|https://github.com/apache/flink/blob/fb38c99a38c63ba8801e765887f955522072615a/flink-python/pyflink/fn_execution/beam/beam_sdk_worker_main.py#L30],
 the value of DEFAULT_BUNDLE_PROCESSOR_CACHE_SHUTDOWN_THRESHOLD_S is set to 
3153600000. This is more than the default value of threading.TIMEOUT_MAX on 
Windows Python. Due to this, "OverflowError: timeout value is too large" error 
is produced.

Full traceback:
{code:java}
File 
"G:\PycharmProjects\PyFlink\venv_from_scratch\lib\site-packages\apache_beam\runners\worker\data_plane.py",
 line 218, in run
while not self._finished.wait(next_call - time.time()):
File "C:\Python38\lib\threading.py", line 558, in wait
signaled = self._cond.wait(timeout)
File "C:\Python38\lib\threading.py", line 306, in wait
gotit = waiter.acquire(True, timeout)
OverflowError: timeout value is too large{code}


> The value of DEFAULT_BUNDLE_PROCESSOR_CACHE_SHUTDOWN_THRESHOLD_S is too large 
> ------------------------------------------------------------------------------
>
>                 Key: FLINK-25883
>                 URL: https://issues.apache.org/jira/browse/FLINK-25883
>             Project: Flink
>          Issue Type: Bug
>         Environment: Windows, Python 3.8
>            Reporter: Mikhail
>            Priority: Minor
>
> In [this 
> line|https://github.com/apache/flink/blob/fb38c99a38c63ba8801e765887f955522072615a/flink-python/pyflink/fn_execution/beam/beam_sdk_worker_main.py#L30],
>  the value of DEFAULT_BUNDLE_PROCESSOR_CACHE_SHUTDOWN_THRESHOLD_S is set to 
> 3153600000. This is more than the default value of threading.TIMEOUT_MAX on 
> Windows Python. Due to this, "OverflowError: timeout value is too large" 
> error is produced.
> Full traceback:
> {code:java}
>  File 
> "G:\PycharmProjects\PyFlink\venv_from_scratch\lib\site-packages\apache_beam\runners\worker\data_plane.py",
>  line 218, in run
>   while not self._finished.wait(next_call - time.time()):
>  File "C:\Python38\lib\threading.py", line 558, in wait
>   signaled = self._cond.wait(timeout)
>  File "C:\Python38\lib\threading.py", line 306, in wait
>   gotit = waiter.acquire(True, timeout)
> OverflowError: timeout value is too large{code}



--
This message was sent by Atlassian Jira
(v8.20.1#820001)

Reply via email to