Github user StephanEwen commented on a diff in the pull request:

    https://github.com/apache/flink/pull/2544#discussion_r80463624
  
    --- Diff: 
flink-runtime/src/main/java/org/apache/flink/runtime/state/filesystem/FsCheckpointStreamFactory.java
 ---
    @@ -301,9 +301,16 @@ public StreamStateHandle closeAndGetHandle() throws 
IOException {
                                        }
                                        else {
                                                flush();
    +
    +                                           long size = -1;
    --- End diff --
    
    Stream position should be okay to determine the state size. All instances I 
checked were accurate there.
    Also, given that the size is more informational and should not be relied 
upon, it should be all the less critical.