https://issues.apache.org/jira/browse/FLINK-30239?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Lijie Wang reassigned FLINK-30239:
----------------------------------

    Assignee: Lijie Wang

> The flame graph doesn't work due to groupExecutionsByLocation has bug
> ---------------------------------------------------------------------
>
>                 Key: FLINK-30239
>                 URL: https://issues.apache.org/jira/browse/FLINK-30239
>             Project: Flink
>          Issue Type: Bug
>          Components: Runtime / REST, Runtime / Web Frontend
>    Affects Versions: 1.16.0, 1.17.0
>            Reporter: Rui Fan
>            Assignee: Lijie Wang
>            Priority: Major
>              Labels: pull-request-available
>             Fix For: 1.17.0, 1.16.1
>
>         Attachments: image-2022-11-30-00-10-48-940.png, 
> image-2022-11-30-00-11-09-728.png, image-2022-11-30-00-14-11-355.png
>
>
> The flame graph cannot be generated forever when multiple tasks in the same 
> TM. It's caused by FLINK-26074
>  
> h1. Root cause:
> A Set cannot be converted to an ImmutableSet during the aggregation of 
> ExecutionAttemptIDs. It will cause only the first ExecutionAttemptID of the 
> TM to be added to the set, the second ExecutionAttemptID will fail.
>  
> !image-2022-11-30-00-14-11-355.png!
>  
>  
>  
> !image-2022-11-30-00-11-09-728.png!
>  
> Exception Info: 
> !image-2022-11-30-00-10-48-940.png!



--