mas-chen commented on code in PR #22303:
URL: https://github.com/apache/flink/pull/22303#discussion_r1152679757


##########
flink-connectors/flink-connector-kafka/src/main/java/org/apache/flink/connector/kafka/sink/KafkaWriter.java:
##########
@@ -420,6 +420,7 @@ private void checkAsyncException() throws IOException {
         if (e != null) {
 
             asyncProducerException = null;
+            numRecordsOutErrorsCounter.inc();

Review Comment:
   The logic for counter is duplicated because it is possible for 
write/flush/WriterCallback-mailbox to throw the exception. When the exception 
is thrown, the counter should also be incremented. 
   
   Ideally, we can increment the counter once when I detect the exception 
(inside the WriterCallback, before the mailbox) but we have no control over the 
Counter and it is not volatile.
   
   I also am questioning the value of such a counter because the exception 
should cause a DAG restart in which metrics should reset. However, the metric 
is already is exposed as public API, so we need to keep it



-- 