Github user mxm commented on a diff in the pull request:

    https://github.com/apache/flink/pull/2671#discussion_r84464167
  
    --- Diff: 
flink-streaming-java/src/main/java/org/apache/flink/streaming/api/windowing/triggers/ContinuousEventTimeTrigger.java
 ---
    @@ -88,9 +96,13 @@ public TriggerResult onProcessingTime(long time, W 
window, TriggerContext ctx) t
        @Override
        public void clear(W window, TriggerContext ctx) throws Exception {
                ReducingState<Long> fireTimestamp = 
ctx.getPartitionedState(stateDesc);
    -           long timestamp = fireTimestamp.get();
    -           ctx.deleteEventTimeTimer(timestamp);
    -           fireTimestamp.clear();
    +           Long timestamp = fireTimestamp.get();
    +           if (timestamp != null) {
    +                   ctx.deleteEventTimeTimer(timestamp);
    +                   fireTimestamp.clear();
    +           } else if (cachedFireTimestamp != null){
    +                   ctx.deleteEventTimeTimer(cachedFireTimestamp);
    +           }
    --- End diff --
    
    The above `else if` block is not correct because there is only one instance 
of the trigger which is reused for each Window. Hence the abstraction using the 
state descriptor to retrieve the appropriate state.


---