[ https://issues.apache.org/jira/browse/FLINK-25565?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17794287#comment-17794287 ]
Thomas Weise commented on FLINK-25565: -------------------------------------- [~martijnvisser] the default behavior did not change. It is necessary to opt into the INT64 mapping, the PR added the config option to the same page (write.int64.timestamp). I agree it would be helpful if the mapping table itself mentions it also though. > Write and Read Parquet INT64 Timestamp > -------------------------------------- > > Key: FLINK-25565 > URL: https://issues.apache.org/jira/browse/FLINK-25565 > Project: Flink > Issue Type: Sub-task > Components: Formats (JSON, Avro, Parquet, ORC, SequenceFile) > Affects Versions: 1.12.0, 1.15.0 > Reporter: Bo Cui > Assignee: Bo Cui > Priority: Major > Labels: pull-request-available, stale-assigned > Fix For: 1.19.0 > > > Flink cannot read parquet files that contain INT64 Timestamp generated by > Spark -- This message was sent by Atlassian Jira (v8.20.10#820010)