Thomas Weise commented on FLINK-25565:
--------------------------------------
[~martijnvisser] the default behavior did not change. It is necessary to opt
into the INT64 mapping, the PR added the config option to the same page
(write.int64.timestamp). I agree it would be helpful if the mapping table
itself mentions it also though.
> Write and Read Parquet INT64 Timestamp
> --------------------------------------
>
> Key: FLINK-25565
> URL: https://issues.apache.org/jira/browse/FLINK-25565
> Project: Flink
> Issue Type: Sub-task
> Components: Formats (JSON, Avro, Parquet, ORC, SequenceFile)
> Affects Versions: 1.12.0, 1.15.0
> Reporter: Bo Cui
> Assignee: Bo Cui
> Priority: Major
> Labels: pull-request-available, stale-assigned
> Fix For: 1.19.0
>
>
> Flink cannot read parquet files that contain INT64 Timestamp generated by
> Spark
--