https://issues.apache.org/jira/browse/FLINK-36412?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Hong Liang Teoh updated FLINK-36412:
------------------------------------
    Affects Version/s: aws-connector-4.3.0

> Retry strategies on Kinesis Sink
> --------------------------------
>
>                 Key: FLINK-36412
>                 URL: https://issues.apache.org/jira/browse/FLINK-36412
>             Project: Flink
>          Issue Type: Improvement
>          Components: Connectors / AWS, Connectors / Kinesis
>    Affects Versions: aws-connector-4.3.0
>            Reporter: Ed Berezitsky
>            Priority: Major
>
> In case of internal Kinesis issues, Kinesis Sink connector crashes and causes 
> application to stop
> {{java.util.concurrent.CompletionException: 
> org.apache.flink.kinesis.shaded.software.amazon.awssdk.core.exception.SdkClientException:
>  Unable to execute HTTP request: connection timed 
> out:<ACCOUNT_ID>.data-kinesis.us-west-2.amazonaws.com/<10.x.x.x>:443 at 
> org.apache.flink.kinesis.shaded.software.amazon.awssdk.utils.CompletableFutureUtils.errorAsCompletionException(CompletableFutureUtils.java:65)
>  at 
> org.apache.flink.kinesis.shaded.software.amazon.awssdk.core.internal.http.pipeline.stages.AsyncExecutionFailureExceptionReportingStage.lambda$execute$0(AsyncExecutionFailureExceptionReportingStage.java:51)}}
>  
> The connector could introduce improved exception/error managing mechanism to 
> allow an application to wait until connection is restored, controlled by 
> additional parameters available for a users of the connector to set in a 
> Flink aopp



--
This message was sent by Atlassian Jira