https://issues.apache.org/jira/browse/FLINK-5355?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15805207#comment-15805207
 ] 

ASF GitHub Bot commented on FLINK-5355:
---------------------------------------

GitHub user skidder opened a pull request:

    https://github.com/apache/flink/pull/3078

    [FLINK-5355] Handle AmazonKinesisException gracefully in Kinesis Streaming 
Connector

    My Flink job that consumes from a Kinesis stream must be restarted at least 
once daily due to an uncaught AmazonKinesisException when reading from Kinesis. 
The complete stacktrace looks like:
    
    ```
    com.amazonaws.services.kinesis.model.AmazonKinesisException: null (Service: 
AmazonKinesis; Status Code: 500; Error Code: InternalFailure; Request ID: 
dc1b7a1a-1b97-1a32-8cd5-79a896a55223)
        at 
com.amazonaws.http.AmazonHttpClient$RequestExecutor.handleErrorResponse(AmazonHttpClient.java:1545)
        at 
com.amazonaws.http.AmazonHttpClient$RequestExecutor.executeOneRequest(AmazonHttpClient.java:1183)
        at 
com.amazonaws.http.AmazonHttpClient$RequestExecutor.executeHelper(AmazonHttpClient.java:964)
        at 
com.amazonaws.http.AmazonHttpClient$RequestExecutor.doExecute(AmazonHttpClient.java:676)
        at 
com.amazonaws.http.AmazonHttpClient$RequestExecutor.executeWithTimer(AmazonHttpClient.java:650)
        at 
com.amazonaws.http.AmazonHttpClient$RequestExecutor.execute(AmazonHttpClient.java:633)
        at 
com.amazonaws.http.AmazonHttpClient$RequestExecutor.access$300(AmazonHttpClient.java:601)
        at 
com.amazonaws.http.AmazonHttpClient$RequestExecutionBuilderImpl.execute(AmazonHttpClient.java:583)
        at 
com.amazonaws.http.AmazonHttpClient.execute(AmazonHttpClient.java:447)
        at 
com.amazonaws.services.kinesis.AmazonKinesisClient.doInvoke(AmazonKinesisClient.java:1747)
        at 
com.amazonaws.services.kinesis.AmazonKinesisClient.invoke(AmazonKinesisClient.java:1723)
        at 
com.amazonaws.services.kinesis.AmazonKinesisClient.getRecords(AmazonKinesisClient.java:858)
        at 
org.apache.flink.streaming.connectors.kinesis.proxy.KinesisProxy.getRecords(KinesisProxy.java:193)
        at 
org.apache.flink.streaming.connectors.kinesis.internals.ShardConsumer.getRecords(ShardConsumer.java:268)
        at 
org.apache.flink.streaming.connectors.kinesis.internals.ShardConsumer.run(ShardConsumer.java:176)
        at 
java.util.concurrent.Executors$RunnableAdapter.call(Executors.java:511)
        at java.util.concurrent.FutureTask.run(FutureTask.java:266)
        at 
java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1142)
        at 
java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:617)
        at java.lang.Thread.run(Thread.java:745)
    ```
    It's interesting that the Kinesis endpoint returned a 500 status code, but 
that's outside the scope of this issue.
    
    I think we can handle this exception in the same manner as a 
ProvisionedThroughputException: performing an exponential backoff and retrying 
a finite number of times before throwing an exception.

You can merge this pull request into a Git repository by running:

    $ git pull https://github.com/skidder/flink skidder/flink-5355

Alternatively you can review and apply these changes as the patch at:

    https://github.com/apache/flink/pull/3078.patch

To close this pull request, make a commit to your master/trunk branch
with (at least) the following in the commit message:

    This closes #3078
    
----
commit 85adf13f62351675e39811b9cb58aa2ac9a9cd4d
Author: Scott Kidder <sc...@mux.com>
Date:   2016-12-16T16:46:54Z

    [FLINK-5355] Handle AmazonKinesisException gracefully in Kinesis Streaming 
Connector

----


> Handle AmazonKinesisException gracefully in Kinesis Streaming Connector
> -----------------------------------------------------------------------
>
>                 Key: FLINK-5355
>                 URL: https://issues.apache.org/jira/browse/FLINK-5355
>             Project: Flink
>          Issue Type: Improvement
>          Components: Kinesis Connector
>    Affects Versions: 1.2.0, 1.1.3
>            Reporter: Scott Kidder
>            Assignee: Scott Kidder
>
> My Flink job that consumes from a Kinesis stream must be restarted at least 
> once daily due to an uncaught AmazonKinesisException when reading from 
> Kinesis. The complete stacktrace looks like:
> {noformat}
> com.amazonaws.services.kinesis.model.AmazonKinesisException: null (Service: 
> AmazonKinesis; Status Code: 500; Error Code: InternalFailure; Request ID: 
> dc1b7a1a-1b97-1a32-8cd5-79a896a55223)
>       at 
> com.amazonaws.http.AmazonHttpClient$RequestExecutor.handleErrorResponse(AmazonHttpClient.java:1545)
>       at 
> com.amazonaws.http.AmazonHttpClient$RequestExecutor.executeOneRequest(AmazonHttpClient.java:1183)
>       at 
> com.amazonaws.http.AmazonHttpClient$RequestExecutor.executeHelper(AmazonHttpClient.java:964)
>       at 
> com.amazonaws.http.AmazonHttpClient$RequestExecutor.doExecute(AmazonHttpClient.java:676)
>       at 
> com.amazonaws.http.AmazonHttpClient$RequestExecutor.executeWithTimer(AmazonHttpClient.java:650)
>       at 
> com.amazonaws.http.AmazonHttpClient$RequestExecutor.execute(AmazonHttpClient.java:633)
>       at 
> com.amazonaws.http.AmazonHttpClient$RequestExecutor.access$300(AmazonHttpClient.java:601)
>       at 
> com.amazonaws.http.AmazonHttpClient$RequestExecutionBuilderImpl.execute(AmazonHttpClient.java:583)
>       at 
> com.amazonaws.http.AmazonHttpClient.execute(AmazonHttpClient.java:447)
>       at 
> com.amazonaws.services.kinesis.AmazonKinesisClient.doInvoke(AmazonKinesisClient.java:1747)
>       at 
> com.amazonaws.services.kinesis.AmazonKinesisClient.invoke(AmazonKinesisClient.java:1723)
>       at 
> com.amazonaws.services.kinesis.AmazonKinesisClient.getRecords(AmazonKinesisClient.java:858)
>       at 
> org.apache.flink.streaming.connectors.kinesis.proxy.KinesisProxy.getRecords(KinesisProxy.java:193)
>       at 
> org.apache.flink.streaming.connectors.kinesis.internals.ShardConsumer.getRecords(ShardConsumer.java:268)
>       at 
> org.apache.flink.streaming.connectors.kinesis.internals.ShardConsumer.run(ShardConsumer.java:176)
>       at 
> java.util.concurrent.Executors$RunnableAdapter.call(Executors.java:511)
>       at java.util.concurrent.FutureTask.run(FutureTask.java:266)
>       at 
> java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1142)
>       at 
> java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:617)
>       at java.lang.Thread.run(Thread.java:745)
> {noformat}
> It's interesting that the Kinesis endpoint returned a 500 status code, but 
> that's outside the scope of this issue.
> I think we can handle this exception in the same manner as a 
> ProvisionedThroughputException: performing an exponential backoff and 
> retrying a finite number of times before throwing an exception.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Reply via email to