Josh Keegan created FLINK-40467:
-----------------------------------
Summary: Flink 2.3 Application Mode managed by the kubernetes
operator can start without submitting the new job after savepoint redeploy
Key: FLINK-40467
URL: https://issues.apache.org/jira/browse/FLINK-40467
Project: Flink
Issue Type: Bug
Components: Kubernetes Operator
Affects Versions: 2.3.0
Reporter: Josh Keegan
With Flink 2.3 Application Mode, we have seen savepoint upgrades complete
successfully but the replacement application cluster sometimes starts without
submitting the new job.
The operator assigns a new Job ID, while the Application ID remains the same as
the previous deployment. The JobManagers are healthy and REST is available, but
the operator reports {{{}MISSING / Job Not Found{}}}. Looking in the UI, the
previous application shows as {{FINISHED}} with no jobs.
Looking into this, it seems that the operator replaces the Job ID during a
savepoint redeployment since the old Job has been stopped. The same logic
doesn't exist for the new Application ID.
We worked around this by setting the Application ID to the Job ID assigned by
the operator in a startup script for our docker image. That way, whenever the
operator rotates the Job ID, our Application ID is also rotated. Since doing
this approx 1 week ago, we've had no issues.
It looks like the operator should manage the Application ID alongside the Job
ID for new Application Mode executions. I think our fix of setting it to be the
same as the Job ID is fine for single Job deployments, but I don't know if more
complex logic is required for multiple Jobs.
Using Flink 2.3 and flink-kubernetes-operator 1.15.0
--