https://issues.apache.org/jira/browse/FLINK-41063?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

ASF GitHub Bot updated FLINK-41063:
-----------------------------------
    Labels: pull-request-available  (was: )

>  DataStream large-record sorting unnecessarily falls back to Kryo for payload 
> serialization
> -------------------------------------------------------------------------------------------
>
>                 Key: FLINK-41063
>                 URL: https://issues.apache.org/jira/browse/FLINK-41063
>             Project: Flink
>          Issue Type: Bug
>          Components: Runtime / Task
>    Affects Versions: 2.3.0, 2.2.1
>         Environment: Observed on Flink 2.2.1; regression tests reproduce the 
> issue and verify the fix on 2.3.0.
>            Reporter: Dominik Dębowczyk
>            Priority: Major
>              Labels: pull-request-available
>
> With {{taskmanager.runtime.large-record-handler}} enabled, both 
> {{FixedLengthByteKeyComparator}} and {{VariableLengthByteKeyComparator}} 
> extract the entire record as a sort key, although comparison only uses the 
> byte-array key and timestamp.
> {{LargeRecordHandler}} then infers a serializer for the complete record 
> instead of reusing the supplied payload serializer. This can unexpectedly 
> select Kryo or fail when generic types are disabled.
> We encountered this with the Apache Beam Flink Runner: {{{}Kryo 
> initialization failed with a classloader conflict during spilling{}}}, 
> surfaced as “The sorter is closed already.” JFR revealed the underlying 
> exception.
> The proposed fix is to extract only the byte-array key and timestamp and 
> return matching flat comparators. This preserves ordering, avoids payload 
> serializer inference, and eliminates redundant payload serialization in the 
> key spill file.



--
This message was sent by Atlassian Jira
(v8.20.10#820010)

Reply via email to