dylanhz created FLINK-41656:
-------------------------------
Summary: Avoid per-record accumulator conversions in keyed batch
sort aggregation
Key: FLINK-41656
URL: https://issues.apache.org/jira/browse/FLINK-41656
Project: Flink
Issue Type: Improvement
Components: Table SQL / Planner
Reporter: dylanhz
h3. Problem
In a keyed batch {{SortAggregate}}, Flink stores the current group's
accumulator in its internal row representation. For {{APPROX_COUNT_DISTINCT}}
(HLL) and variance aggregates such as {{VAR_POP}} (Welford), each call to
{{accumulate}} converts the accumulator to a Java object and converts it back
after the update. In a two-phase plan, the global aggregate also performs this
round trip on its target accumulator for each incoming partial.
Rows for the same key are contiguous. Both implementations create a fresh
accumulator for each group and can update it directly until the key changes.
The repeated conversions therefore add work to every update without affecting
the result.
h3. Proposed change
Keep the current group's HLL and Welford accumulators in their Java
representation in keyed batch sort aggregation. In a two-phase plan, keep the
existing internal row format for partial results exchanged between the local
and global operators. Apply the optimization automatically for these two
implementations.
h3. Compatibility
Other UDAFs must retain their existing per-record conversion behavior. For
example, consider a UDAF with a {{BigDecimal}} accumulator field declared as
{{DECIMAL(10, 2)}}. If each of three input rows adds {{0.004}}, converting the
field after every update rounds it to {{0.00}} each time. Deferring conversion
until the group ends would instead round {{0.012}} to {{0.01}}, changing the
SQL result.
Cover one-phase and two-phase aggregation for HLL and Welford, and retain a
regression test that runs HLL alongside this DECIMAL UDAF in the same operator.
--
This message was sent by Atlassian Jira