https://issues.apache.org/jira/browse/IGNITE-7837?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Alexey Kuznetsov closed IGNITE-7837.
------------------------------------

Not relative any more.

> Web console: list-editable new item button behaves incorrectly
> --------------------------------------------------------------
>
>                 Key: IGNITE-7837
>                 URL: https://issues.apache.org/jira/browse/IGNITE-7837
>             Project: Ignite
>          Issue Type: Bug
>          Components: wizards
>            Reporter: Ilya Borisov
>            Assignee: Ilya Borisov
>            Priority: Minor
>
> *How to reproduce:*
>  # Open advanced configuration, domain model editing.
>  # Open query section, add one alias, click elsewhere.
>  # Click on added alias to enter edit mode again.
>  # Click on "Add new alias to query".
>  
> *What happens:*
> First alias edit form closes, but new alias is not added.
>  
> *What should happen:*
> First alias edit form should close, another (second) alias should be added, 
> second alias should be in edit mode.
>  
> *Notes:*
> I did some research on the issue, the possible cause of the issue lies either 
> in {{on-focus-out directive}} (used inside {{list-editable}}) or 
> {{list-editable}} directive, or both. If the {{delete this._cache[idx]}} 
> expression in {{stopEditView}} method of {{list-editable}} component 
> controller is wrapped with a {{$timeout(..., 150)}} everything works as 
> expected, except that 150ms of added delay makes UX perceptibly worse.
>  
> *What to do:*
>  Investigate the cause of the issue described above and fix the incorrect 
> behavior, preferably not the way described in notes section.



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to