Sahil Takiar created IMPALA-9253:
------------------------------------

             Summary: Blacklist additional posix error codes for failed 
DataStreamService RPCs
                 Key: IMPALA-9253
                 URL: https://issues.apache.org/jira/browse/IMPALA-9253
             Project: IMPALA
          Issue Type: Improvement
            Reporter: Sahil Takiar


Filing as a follow up to 
[IMPALA-9137|http://issues.cloudera.org/browse/IMPALA-9137], 
[IMPALA-9137|http://issues.cloudera.org/browse/IMPALA-9137] blacklists a node 
if a RPC fails with specific posix error codes:
 * 107 = ENOTCONN: Transport endpoint is not connected
 * 108 = ESHUTDOWN: Cannot send after transport endpoint shutdown
 * 111 = ECONNREFUSED: Connection refused

These codes were produced by running a query, killing a node running that 
query, and then seeing what error codes the query failed with.

There may be other error codes that are worth using for node blacklisting as 
well. One way to come up with more error codes is to use iptables to introduce 
network faults between Impala processes and see how RPCs fail.



--