Yan Xu created MESOS-7215:
-----------------------------

             Summary: Master sends ShutdownFrameworkMessage for all 
partition-aware frameworks
                 Key: MESOS-7215
                 URL: https://issues.apache.org/jira/browse/MESOS-7215
             Project: Mesos
          Issue Type: Bug
            Reporter: Yan Xu


Prior to the partition-awareness work MESOS-5344, upon agent reregistration 
after it has been removed, the master only sends ShutdownFrameworkMessages to 
the agent for frameworks that it knows have been torn down. 
With the new logic in MESOS-5344, Mesos is now sending 
{{ShutdownFrameworkMessages}} to the agent for all non-partition-aware 
frameworks (including the ones that are still registered)

This is problematic. The offer from this agent can still go to the same 
framework which can then launch new tasks. The agent then receives tasks of the 
same framework and ignores them because it thinks the framework is shutting 
down. The framework is not shutting down of course, so from the master and the 
scheduler's perspective the task is pending in STAGING forever until the next 
agent reregistration, which could happen much later.

This also makes the semantics of `ShutdownFrameworkMessage` ambiguous: the 
agent is assuming the framework to be going away (and act accordingly) when 
it's not. 



--
This message was sent by Atlassian JIRA
(v6.3.15#6346)

Reply via email to