https://issues.apache.org/jira/browse/METRON-1050?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16092464#comment-16092464
 ] 

ASF GitHub Bot commented on METRON-1050:
----------------------------------------

Github user JonZeolla commented on a diff in the pull request:

    https://github.com/apache/metron/pull/656#discussion_r128136238
  
    --- Diff: metron-analytics/metron-profiler/README.md ---
    @@ -277,25 +282,103 @@ The values can be changed on disk and then the 
Profiler topology must be restart
     
     | Setting                               | Description
     |---                                    |---
    -| profiler.workers                      | The number of worker processes 
to create for the topology.
    -| profiler.executors                    | The number of executors to spawn 
per component.
    -| profiler.input.topic                  | The name of the Kafka topic from 
which to consume data.
    -| profiler.output.topic                 | The name of the Kafka topic to 
which profile data is written.  Only used with profiles that use the [`triage` 
result field](#result).
    -| profiler.period.duration              | The duration of each profile 
period.  This value should be defined along with 
`profiler.period.duration.units`.
    -| profiler.period.duration.units        | The units used to specify the 
`profiler.period.duration`.
    -| profiler.ttl                          | If a message has not been 
applied to a Profile in this period of time, the Profile will be forgotten and 
its resources will be cleaned up. This value should be defined along with 
`profiler.ttl.units`.
    -| profiler.ttl.units                    | The units used to specify the 
`profiler.ttl`.
    -| profiler.hbase.salt.divisor           | A salt is prepended to the row 
key to help prevent hotspotting.  This constant is used to generate the salt.  
Ideally, this constant should be roughly equal to the number of nodes in the 
Hbase cluster.
    -| profiler.hbase.table                  | The name of the HBase table that 
profiles are written to.
    -| profiler.hbase.column.family          | The column family used to store 
profiles.
    -| profiler.hbase.batch                  | The number of puts that are 
written in a single batch.
    -| profiler.hbase.flush.interval.seconds | The maximum number of seconds 
between batch writes to HBase.
    -
    -After altering the configuration, start the Profiler.
    +| [`profiler.input.topic`](#profilerinputtopic) | The name of the Kafka 
topic from which to consume data.
    +| [`profiler.output.topic`](#profileroutputtopic) | The name of the Kafka 
topic to which profile data is written.  Only used with profiles that define 
the [`triage` result field](#result).
    +| [`profiler.period.duration`](#profilerperiodduration) | The duration of 
each profile period.  
    +| [`profiler.period.duration.units`](#profilerperioddurationunits) | The 
units used to specify the 
[`profiler.period.duration`](#profilerperiodduration).  
    +| [`profiler.workers`](#profilerworkers) | The number of worker processes 
for the topology.
    +| [`profiler.executors`](#profilerexecutors) | The number of executors to 
spawn per component.
    +| [`profiler.ttl`](#profilerttl) | If a message has not been applied to a 
Profile in this period of time, the Profile will be forgotten and its resources 
will be cleaned up. 
    +| [`profiler.ttl.units`](#profilerttlunits) | The units used to specify 
the `profiler.ttl`.
    +| [`profiler.hbase.salt.divisor`](#profilerhbasesaltdivisor) | A salt is 
prepended to the row key to help prevent hotspotting. 
    +| [`profiler.hbase.table`](#profilerhbasetable) | The name of the HBase 
table that profiles are written to.
    +| [`profiler.hbase.column.family`](#profilerhbasecolumnfamily) | The 
column family used to store profiles.
    +| [`profiler.hbase.batch`](#profilerhbasebatch) | The number of puts that 
are written to HBase in a single batch.
    +| 
[`profiler.hbase.flush.interval.seconds`](#profilerhbaseflushintervalseconds) | 
The maximum number of seconds between batch writes to HBase.
    --- End diff --
    
    Is there a reason to not use fixed width columns?  I know this is not a 
very complicated table, but in the past [we have had 
issues](https://github.com/apache/metron/commit/f6c253f44fe7ca5a6b31c46075f537940751c934#diff-dba284384333126318019f762880ace4)
 where a table formatting mistake was causing information to fail to display 
and was hard to identify when looking only at the raw markdown.  No strong 
opinions either way.


> Improve Docs of `profiler.period.duration` 
> -------------------------------------------
>
>                 Key: METRON-1050
>                 URL: https://issues.apache.org/jira/browse/METRON-1050
>             Project: Metron
>          Issue Type: Bug
>    Affects Versions: 0.4.0
>            Reporter: Nick Allen
>            Assignee: Nick Allen
>             Fix For: 0.4.1
>
>
> It is a common mistake for new user's of the Profiler, to alter the 
> Profiler's `profiler.period.duration` property, but not alter the 
> corresponding `profiler.client.period.duration` property.  The new user is 
> then unable to read the profile data as they would expect.
> More should be done, but this JIRA focuses on improving the documentation 
> around this common error experienced by new users.



--