https://issues.apache.org/jira/browse/NIFI-8610?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17349070#comment-17349070
 ] 

Peter Gyori commented on NIFI-8610:
-----------------------------------

Understood. Thank you for checking!

> Invalid bigdecimal values in ORC when multiple avro records provided
> --------------------------------------------------------------------
>
>                 Key: NIFI-8610
>                 URL: https://issues.apache.org/jira/browse/NIFI-8610
>             Project: Apache NiFi
>          Issue Type: Bug
>          Components: Core Framework
>    Affects Versions: 1.13.2
>            Reporter: Dominik Przybysz
>            Priority: Major
>              Labels: pull-request-available
>          Time Spent: 10m
>  Remaining Estimate: 0h
>
> Processor: convertAvroToORC
> Input:  flow file contains a lot of avro records with decimal values as bytes 
> with logical type decimal
> Output: ORC file with different values for decimal values
> Reason: AvroReader used in processor reuses previous generic record when 
> fetching next one
> Solution: Don't reuse generic records when reading records from flow file



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to