https://issues.apache.org/jira/browse/NIFI-16064?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Jens M Kofoed updated NIFI-16064:
---------------------------------
    Description: 
If you have created a "Generic process group" with a remote input port inside 
which you put in version control. And you reuse this PG multiple places, the 
name of the "Remote Input port" automattacly change to "copy of xxxx". Sinse 
you are not allowed to have 2 remote input ports with the same name. I belive 
that this is also why a change in the name does not consider a "local change". 
Next you change the "copy of xxxx" to something meaningfull - All is fine.

Issue: If you have made other changes to that PG and upload a new version. All 
other PG which is connected to that version-control also need updates. Now when 
you update a PG to the new version the input port change the name back to what 
is defined in the saved version in registry.

  was:
When you have created a "Generic process group" with a remote input port inside 
which is under version control. The name of the "Remote Input port" has to 
change when reusing that PG multiple places. You are not allowed to have 2 
remote input ports with the same name. I belive that this is also why a change 
in the name does not consider a "local change"

Issue: If you have made a change and you need to update a PG to the new version 
the input port change the name back to what is defined in the saved version in 
registry. 


> The name of a remote inputport change name when updating from version control
> -----------------------------------------------------------------------------
>
>                 Key: NIFI-16064
>                 URL: https://issues.apache.org/jira/browse/NIFI-16064
>             Project: Apache NiFi
>          Issue Type: Bug
>          Components: Core UI
>    Affects Versions: 2.9.0, 2.10.0
>            Reporter: Jens M Kofoed
>            Priority: Major
>
> If you have created a "Generic process group" with a remote input port inside 
> which you put in version control. And you reuse this PG multiple places, the 
> name of the "Remote Input port" automattacly change to "copy of xxxx". Sinse 
> you are not allowed to have 2 remote input ports with the same name. I belive 
> that this is also why a change in the name does not consider a "local 
> change". Next you change the "copy of xxxx" to something meaningfull - All is 
> fine.
> Issue: If you have made other changes to that PG and upload a new version. 
> All other PG which is connected to that version-control also need updates. 
> Now when you update a PG to the new version the input port change the name 
> back to what is defined in the saved version in registry.



--
This message was sent by Atlassian Jira
(v8.20.10#820010)

Reply via email to