Matt Gilman commented on NIFI-3963:
-----------------------------------

[~JPercivall] I have been unable to reproduce this issue with the supplied 
steps. I've attached a screenshot showing the yield duration being honored 
throughout multiple transmission cycles. 

Any other details that may help me reproduce? Can you check the flow.xml.gz to 
see the configuration value in there?

> Remote Process Group does not honor yield duration if transmission is 
> disabled then reenabled
> ---------------------------------------------------------------------------------------------
>
>                 Key: NIFI-3963
>                 URL: https://issues.apache.org/jira/browse/NIFI-3963
>             Project: Apache NiFi
>          Issue Type: Bug
>    Affects Versions: 1.2.0
>            Reporter: Joseph Percivall
>
> To reproduce, create two NiFi instances properly set up for unsecure or 
> secure  S2S. One on side add an input/output port and the other an RPG. 
> Enable transmission on the RPG. Stop the instance with the port. On the 
> running instance see NiFi honoring the yield duration. Then stop and start 
> transmission, see NiFi repeatedly attempt to connect to the instance (I saw 
> multiple log messages per millisecond). 



--