[ https://issues.apache.org/jira/browse/NIFI-5092?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16450187#comment-16450187 ]
ASF GitHub Bot commented on NIFI-5092: -------------------------------------- Github user mattyb149 commented on the issue: https://github.com/apache/nifi/pull/2643 Reviewing... > S2S Bulletin Reporting Task will not send recent bulletins after a restart > -------------------------------------------------------------------------- > > Key: NIFI-5092 > URL: https://issues.apache.org/jira/browse/NIFI-5092 > Project: Apache NiFi > Issue Type: Bug > Components: Extensions > Affects Versions: 1.2.0, 1.3.0, 1.4.0, 1.5.0, 1.6.0 > Reporter: Pierre Villard > Assignee: Pierre Villard > Priority: Major > > Bulletins are stored in memory by NiFi on a 5-minutes rolling window. Each > bulletin has a bulletin ID and it starts with the value 0. Upon NiFi > restarts, the new generated bulletins will also have an ID starting with the > value 0. > Currently the reporting task is locally storing the ID of the last bulletin > sent through S2S. But this should not be the case because if the last > bulletin ID is X when NiFi is restarted, then all new generated bulletins > with ID <= X will be ignored. > The state management of this reporting task should be completely removed. > Starting/stopping the reporting task won't be impacting the behavior since > the ID of the last bulletin sent is stored in local variable. > *Current workaround* - after a NiFi restart, stop the reporting task, clear > the state of the reporting task and start the reporting task. -- This message was sent by Atlassian JIRA (v7.6.3#76005)